Cheat sheet: RAID levels

What each RAID level does, how many disks it needs, how many failures it survives and when to use it.

RAID combines several disks into one logical volume, for speed, for safety or both. It is not a backup: it protects against a disk failing, not against deleting a file, a virus, a fire or a controller fault.

Level Minimum disks Usable space Survives Speed Good for
RAID 0 (striping) 2 All of it (n) Nothing. One disk fails, all data is lost Fastest reads and writes Scratch space, video editing, anything you can recreate
RAID 1 (mirroring) 2 Half (n / 2) 1 disk in each mirror Fast reads, normal writes Operating system disks, small important volumes
RAID 5 (stripe plus parity) 3 n - 1 1 disk Good reads, slower writes File servers, general purpose
RAID 6 (double parity) 4 n - 2 2 disks Good reads, slower writes Large arrays of big disks
RAID 10 (mirrored stripes) 4 Half (n / 2) 1 disk per mirror pair (at least 1) Fast reads and writes Databases and busy virtual machines

How to choose

  • Need speed and can lose the data: RAID 0.
  • Two disks, want safety: RAID 1.
  • Capacity and some safety, mostly reads: RAID 5. With very large disks, prefer RAID 6, because a rebuild takes a long time and a second failure during it loses everything in RAID 5.
  • Lots of small writes and cannot slow down: RAID 10.

Worked example

Six 4 TB disks:

Level Usable space
RAID 0 24 TB
RAID 5 20 TB
RAID 6 16 TB
RAID 10 12 TB

When a disk fails

  1. Do not panic and do not pull more than one disk. The array is running without a safety net.
  2. Confirm which disk it is (the controller, or cat /proc/mdstat on Linux software RAID).
  3. Replace it with the same size or larger and start the rebuild.
  4. Keep the data backed up before, during and after. A rebuild stresses every remaining disk.
  5. Record the failure and the replacement in your service log.

Hardware, software and hot spares

  • Hardware RAID is done by a controller card. Software RAID is done by the operating system (Linux mdadm, Windows Storage Spaces, ZFS).
  • A hot spare is an idle disk that takes over automatically when one fails, shortening the time you run unprotected.