Case File: Two Speakers Are Not Twice As Loud
The neighbours say that the evening was twice as loud as the soundcheck, and the organiser says that two speakers must be twice as loud as one. Work out the level of each source at the listening position (the level at one metre minus twenty times the logarithm of the distance), add the sources as powers and not as plain numbers, find the loudest, and say whether the venue limit is exceeded. Run it on set-ups that you cannot see, including two equal sources and no sources. The set-up is generated for you alone.
Sabi Logistics · Show 1
Two Speakers Are Not Twice As Loud
The council has sent a noise warning to the depot hall after the Saturday event, and the organiser says that nothing was changed since the soundcheck
Yemi Event manager ·
Yemi. The council has sent us a noise warning after Saturday’s event. The organiser says that “nothing was changed since the soundcheck” except that two more speakers were switched on for the back of the hall, and that two speakers are twice as loud as one, so the neighbours must be exaggerating.
I have the list of sources that reach the spot where the council measured: each makes a known level at one metre, and is a known distance away. The limit at that spot is a number of dB. Please work out the level of each source there, the combined level, which source is the loudest, and whether we are over the limit.
The brief
What you need to know first.
- Distance. In the open air the level falls by
20 x log10(distance in metres)below the level at 1 metre: 6 dB for every doubling of the distance (and 20 dB for ten times the distance). At 1 metre there is no loss. - Adding sources. Decibels are logarithmic: you cannot add them like ordinary numbers. Turn each level into power,
10 ** (level / 10), add the powers, and turn the sum back with10 x log10(...). Two equal sources add only 3 dB; a source 10 dB quieter than another adds only 0.4 dB to it. - The loudest. The source with the highest level at the listener (a tie goes to the name that sorts first;
Nonefor no sources). Over the limit means the combined level is strictly above the limit. - Round every level to 3 decimals. With no sources the combined level is
Noneand the limit is not exceeded. - Fill in
level_at,mix(req)returning{"levels", "combined_db", "loudest", "over_limit"}, thenresultandcombined_db. The checks runmixon set-ups that you cannot see: two equal sources at 1 m (exactly 3.010 dB more than one), a distance of 1 m, and no sources.
The lab gives you the data for this case, invented and generated for you alone.
Preparing your data…
On the bench
The lab checked the arithmetic with a script. These are the measurements and tests that show the same thing at a real venue.
| You want to | Do this | What you see |
|---|---|---|
| measure the level at the place where a limit applies | Use a calibrated sound level meter set to A-weighting at that place, and log the reading every few minutes | the real level in dBA over time, to compare with the limit |
| check the 6 dB per doubling of distance | Play pink noise and measure at 2 m, 4 m and 8 m from the speaker outdoors | a fall of about 6 dB each time the distance doubles |
| see what adds to the neighbours | Measure at the neighbour boundary with the sound system on and then off | the difference that your system makes over the background |
Keep levels safe for hearing, and never work with mains power, rigging or amplifier wiring unless you are trained and permitted.
Yemi: “So two speakers add three decibels, not double. But the council says that three decibels is a big change. Is that right?”
🔒 The debrief unlocks when you close the case. Finish the lab above.
The debrief
Yemi: “So the number is small, but the ear and the rules treat it as large.”
What a senior sound engineer would do next. Know the rules of thumb: +3 dB is a doubling of the power (the speakers) and a change that you can just hear; +10 dB sounds about twice as loud; 6 dB per doubling of distance in the open air (less in a room, where reflections help). That is why ten speakers are not ten times louder, and why the neighbours hear the bass, which spreads in all directions and travels far. Measure with a calibrated sound level meter set to A-weighting (dBA) with fast or slow response as the rule says, at the place where the limit applies, before the event with pink noise and during it, and log the readings every few minutes. Use the limits and curfews of the venue and the council as part of the production plan, and control the source: delays and aim the speakers into the hall, cardioid sub arrays to reduce bass behind the stage, no speakers pointing at houses. Tell the neighbours in advance and give them a phone number.
The trap. Adding decibels as numbers: 100 dB plus 100 dB is 103 dB, not 200, and 100 plus 90 is only 100.4.
Write the noise level note
Write the note for the event manager: how the level of each source at the measuring spot is worked out (20 x log10 of the distance below the level at 1 metre), how sources are added (as powers, not as plain numbers: two equal sources add 3 dB), the levels and the combined level in the case, the loudest source and whether the limit was exceeded, why the organiser was wrong that two speakers are twice as loud, and what to do (calibrated A-weighted measurements at the right place, logging, aiming and delays, cardioid subs, telling neighbours, a limit in the production plan).
🧪 Want to practise this on your own computer? See how to set up your lab →