The Oscilloscope and Waveforms
See signals change over time: what an oscilloscope displays, volts per division, time per division, triggering, probes and the x10 setting, measuring frequency, period, peak-to-peak, RMS and duty cycle, bandwidth and sample rate, and typical signals you will meet.
1. What an oscilloscope shows
A multimeter gives one number. An oscilloscope draws a graph of voltage against time, so you can see how a signal changes: its shape, speed, noise, glitches and timing. It is the main tool for debugging anything that moves faster than your eyes can follow.
The screen is a grid of divisions (usually 10 horizontal by 8 vertical). Two knobs set the scale:
| Control | Unit | Meaning |
|---|---|---|
| Vertical: volts per division (V/div) | volts | How many volts each vertical square represents |
| Horizontal: time per division (s/div) | seconds | How much time each horizontal square represents |
Example: at 1 V/div and 1 ms/div, a wave that spans 3 divisions tall and has one cycle every 4 divisions has a peak-to-peak of 3 V and a period of 4 ms (250 Hz).
2. Measurements from the trace
| Measurement | Definition | Example |
|---|---|---|
| Period (T) | Time for one full cycle | 2 ms |
| Frequency (f) | Cycles per second, f = 1 / T | 500 Hz |
| Peak (Vp) | Maximum voltage from the zero line | 2.5 V |
| Peak-to-peak (Vpp) | Maximum minus minimum | 5 V |
| RMS | The heating-equivalent DC value; for a sine wave Vrms = Vp / √2 ≈ 0.707 × Vp | 1.77 V for 2.5 V peak |
| Duty cycle | High time divided by period, as a percentage | 20 % |
| Rise time | Time to go from 10 % to 90 % of the step | 20 ns |
The average of a square wave that switches between 0 and V_high with duty D is V_high × D: a 5 V signal at 20 percent duty averages 1 V, which is how PWM (pulse-width modulation) dims an LED or sets a motor’s speed.
3. Using a scope step by step
- Probe. Clip the ground lead to the circuit’s ground and the tip to the signal. Set the probe to x10 (and the scope channel to match) for most work: it loads the circuit less and handles higher voltages.
- Compensate the probe once with the scope’s calibration output (a square wave) so that the edges look square, not rounded or overshooting.
- Set coupling. DC coupling shows the whole signal including its offset; AC coupling blocks the DC component to look at small ripple on top.
- Set the scales. Choose a V/div so the signal fills about two thirds of the screen, and a time/div that shows a few cycles.
- Trigger. Select the channel, a rising or falling edge, and a level inside the signal. The trace should now stand still.
- Measure with the cursors or the automatic measurements (frequency, Vpp, mean, RMS), and check them against the grid by eye.
4. Bandwidth and sample rate
- Bandwidth is the frequency at which the scope’s displayed amplitude has fallen by 3 dB (about 30 percent). A 100 MHz scope measures a 100 MHz sine as only 70 percent of its true height. Pick a scope with at least three to five times the highest frequency you want to measure; for square waves the harmonics reach much higher than the repetition rate.
- Sample rate (samples per second) should be at least five to ten times the signal frequency for a faithful picture. Too slow and the display shows a false, slower waveform (aliasing).
- Probe capacitance and the ground lead’s inductance cause ringing on fast edges; use the short ground spring on the probe tip for high speeds.
5. Waveforms you will meet
| Waveform | Where | What to notice |
|---|---|---|
| DC | Battery, regulator | A flat line; look for ripple and noise |
| Sine | Mains, audio, oscillators | Smooth; frequency and amplitude |
| Square / pulse | Clocks, PWM, logic | Rise and fall times, overshoot, duty cycle |
| Triangle and sawtooth | Ramp generators, RC charging | Linearity |
| Exponential | RC charge and discharge | Time constant (63 percent point) |
| Noise and glitches | Anywhere | A short spike can reset a microcontroller |
6. On your bench
- Probe the scope’s own calibration signal. Read its frequency, Vpp and duty cycle and compare with the label.
- Use a function generator (or a microcontroller PWM pin) to produce a 1 kHz square wave. Read the period and calculate the frequency. Change the duty cycle and watch the average with a multimeter.
- Build the RC circuit from the capacitor lesson (10 kΩ, 100 nF) and watch the charging curve on a 100 Hz square wave. Measure the time to 63 percent.
- Probe a 5 V supply rail with a microcontroller running. Use AC coupling and 20 mV/div to see the ripple and spikes.
- Observe a push button bouncing on a pull-up pin.
7. Hands-on lab: scope measurements
8. Common mistakes
| Mistake | Better |
|---|---|
| Probe set to x1 while the scope assumes x10 (or the reverse) | Match the channel attenuation to the probe switch |
| No probe compensation | Adjust to a clean square wave using the calibration signal |
| Unstable trace | Set the trigger source, edge and level |
| Reading the wrong V/div or time/div | Look at the on-screen scale values or use cursors |
| Probing mains circuits with the earthed ground clip | Use isolation or avoid it entirely |
| A scope too slow for the signal | Bandwidth 3 to 5 times the signal, sample rate at least 5 to 10 times |
9. Key takeaways
- A scope plots voltage versus time; V/div and time/div set the scale.
- f = 1 / T, Vpp = max − min, Vrms = Vp / √2 for a sine, duty = high / period.
- The trigger stabilises the picture; set probe x10 and compensate it.
- Choose bandwidth and sample rate well above the signal.
- Use the scope for ripple, noise, timing, bounce and edges that a multimeter cannot show.
A PWM output is 3.3 V high at 1 kHz with a 25 percent duty cycle. What does the scope show for the period and high time, and what does a multimeter read on DC?
The period is 1 ms and the high time is 0.25 ms. A multimeter on a DC range averages the signal and reads about 3.3 × 0.25 = 0.825 V.
Can You Explain It?
Close the lesson and answer these without looking back. The goal isn't the wording — it's whether you've formed a usable mental model.
- Explain what volts per division and time per division mean and how to read a trace.
- Describe how triggering stabilises a waveform.
- Explain how bandwidth and sample rate affect what you see.
🧪 Want to practise this on your own computer? See how to set up your lab →